In applications from chemical processing to plastics to food processing, heavy-duty industrial cooling towers provide effective cooling.


Thermal Care

Fiberglass Cooling Tower Ships Fully Assembled

PC 01-0222 Industrial Cooling Towers ThermalCare

Series FC is designed for outdoor use in industrial manufacturing locations and includes a 10-year warranty on the shell and a five-year warranty on the motor. The 100 to 240 ton tower ships assembled with the fan motor and fan blade removed to prevent shipping damage. Constructed of corrosion-resistant materials, the tower has a fiberglass tower casing and basin, reinforced fiberglass internal structural supports and stainless steel fan support and fasteners. The stainless steel fan guard provides protection from debris entering fan assembly, and the fill, drift eliminators, louvers and water distribution system are constructed of PVC.

Thermal Care | 888-828-7387 | thermalcare.com


SPX Cooling

Cooling Tower with Copper, Stainless Steel or HDG Steel Coils

PC 01-0222 Industrial Cooling Towers SPX Cooling

Model MH is offered with three coil materials to suit the needs of the application. Model MH Element is equipped with copper coils, which provide corrosion resistance and improved heat transfer. The fluid coolers also are available with coils of either HDG steel or stainless steel. The company also offers a hybrid system that combines the functionality of a cooling tower and a heat exchanger and utilizes a combination of evaporative fill media and prime surface coils.

SPX Cooling | 800-462-7539 | spxcooling.com


Evapco

Large-Module Cooling Tower for Industrial Processes

PC 01-0222 Industrial Cooling Towers Evapco

AT Atlas counterflow cooling towers are designed in large, preassembled modules for ease of rigging and installation. The cooling towers range in capacity from 1,484 to 2,386 nominal tons per cell, providing up to 60 percent more cooling capacity per cell, while requiring up to 40 percent less fan power per ton of cooling compared to traditional factory assembled cooling towers, says the manufacturer. Available in Type 304 or Type 316 stainless steel – including the entire basin, support structure, vertical columns, louver frames and plenum.

Evapco | 410-756-2600 | www.evapco.com


Baltimore Aircoil Co.

Fan System for Cooling in Mission-Critical Environments

PC 01-0222 Industrial Cooling Towers Review Baltimore Aircoil Co.

Enduradrive has permanent-magnet, direct-drive technology, in which the fan motor is directly coupled to the fan. The design of the fan system eliminates the need for intermediary moving parts like gears or belts, says the manufacturer. The design is engineered so that the motor, variable-frequency drive (VFD) and cooling tower work together. Features such as upgraded insulation, a double O-ring, a drive-end seal and an integrated drain reduce the risk and cost of failures due to moisture ingress. The fan system is engineered and CTI certified for extreme duty and to withstand thermal and vibration rigors of cooling tower operation.

Baltimore Aircoil Co. | 410-799-6200 | baltimoreaircoil.com


AEC, ACS Group

Fiberglass Cooling Towers Have UV Protection for Long Service Life

PC 01-0222 Industrial Cooling Towers Review AEC, ACS Group

Series FG offer corrosion resistance and energy efficiency. For cooling requirements at 85°F (29.4°C) and above, water consumption may be reduced by 98.5 percent through the use of cooling towers to remove process heat. Features include an induced-draft design, balancing valve and pressure gauge, factory-tuned fan-blade pitch, PVC fill and drift eliminators with UV protection, energy-efficient fan motor, vertical air discharge and a large inspection/access door. The lightweight, noncorrosive fiberglass shell with fiberglass side seams is coated with a UV inhibitor.

AEC, ACS Group | 262-641-8600 | aecinternet.com


Dry Coolers Inc.

Counterflow Cooling Tower Uses Copper Exchanger to Cool Process Water

PC 01-0222 Industrial Cooling Towers Review Dry Coolers, Inc.

A counterflow tower with a built-in copper tube heat exchanger for cooling process water, the MW Series has 0.625" heavy-wall copper tubes for heat transfer and corrosion resistance. Clean process fluid circulates from the facility through the copper-tube heat exchanger inside the cooling tower. Fans on top of the tower draw air through louvers on the side of the tower. The air passes upward through the fill material over the copper-tube heat exchanger. Cool water from the tower’s stainless-steel basin is pumped over the heat exchanger tubes. As the water exchanges heat with the air, a small amount of water evaporates, aiding the fluid cooling process. The cooling tower fans turn on and off as needed to regulate the water temperature.

Dry Coolers Inc. | 800-525-8173 | drycoolers.com


Delta Cooling Towers Inc.

Induced-Draft Cooling Tower Includes PVC Water-Distribution System

PC 01-0222 Industrial Cooling Towers Review Delta Cooling Towers Inc.

An induced-draft, counterflow cooling tower, the TM Series is available in single-unit capacities from 250 to 2,500 cooling tons. Standard features include seamless double-wall HDPE shell, corrosionproof construction, direct-drive fan system and totally enclosed VFD-rated motors. 

Factory assembled to simplify installation, the tower has a 20-year shell warranty. Other features include a PVC water-distribution system with nonclog, large-orifice, removable nozzles and high efficiency PVC fill.

Delta Cooling Towers Inc. | 973-586-2201 | deltacooling.com


Global Treat Inc.

Chemical Dilution Trough for Cooling Towers

PC 01-0222 Industrial Cooling Towers Review Global Treat Inc

Over time, acid feed systems will likely cause long-term damaging effects to cooling tower basins and equipment if chemicals are not mixed properly. Designed for use with water treatment chemicals like chlorine, corrosion inhibitors and cooling tower dispersants used in cooling towers, the gravity-flow chemical dilution trough is designed to dilute chemicals before they enter the cooling tower water basin. The Acid Eddy is offered in three sizes: Mega, which is recommended for higher flow chemical applications of up to 750 gal/day; Macro, which is for chemical flow of up to 500 gal/day; and Micro, which is for chemical flow applications of 250 gal/day or less.

Global Treat Inc. | 281-370-3425 | globaltreat.com


Air Solution Co.

Cottonwood Filter Screens for Cooling Towers, Air Cooled Chillers

PC 01-0222 Industrial Cooling Towers Review Air Solution Co.

Cottonwood filter screens eliminate clogging of fill and strainers as well as sludge buildup in cooling towers. Less contamination means facilities can avoid cleaning solvents and power washing of chiller or condenser coils. Facilities can save annually in energy, downtime, lost productivity and maintenance costs. Compatible with all mechanical equipment brands, the air-intake filter screens are offered in 10 styles. From small condenser and chiller coils to large cooling towers and intake openings that require fast setup or take down, air-intake filtration systems can protect valuable equipment from airborne debris.

Air Solution Co. | 800-819-2869 | airsolutioncompany.com


Cooling Tower Depot Inc.

Counterflow Cooling Tower Incorporates Douglas Fir Construction

PC 01-0222 Industrial Cooling Towers Review Cooling Tower Depot Inc.

Heavy-duty, industrial-grade tower is outfitted with off-set or low fouling film-fill material to provide maximum cooling for a range of water quality conditions. Offering the durability of a Douglas-Fir structure, the CFD Series is engineered to withstand the daily rigors of industrial processing plants, power plants, and oil refineries. In order to enhance its biological defenses, all Douglass-fir structure members are pressure treated after fabrication to provide a longer service life. The film-fill material is selected to meet the unique water quality of each application to ensure optimum cooling performance.

Cooling Tower Depot Inc. | 877-243-3945 | coolingtowerdepot.com


Berg Chilling Systems

Cooling Towers Constructed with Fiberglass-Reinforced Casings

Manufactured of extra-thick fiberglass to provide low maintenance performance, fiberglass cooling towers are supplied fully assembled on a structural steel, integral base to ease installation. Features include fiberglass-reinforced polyester casings, high efficiency PVC fill, standard NEMA frame TEFC motors and low speed propeller fans. A UV inhibitor is added to the gel coat applied to the water basin to eliminate fiberglass deterioration and pigment fade.

Berg Chilling Systems | 416-755-2221 | berg-group.com